Airtightness & Air Sealing

Compiled by the Passive House Accelerator editorial team – Editorial review by Jay Fox, August 6, 2026

A tight envelope shuts down the uncontrolled airflow that drains conventional buildings of energy and stops air from carrying moisture into wall and roof assemblies where it can condense and feed rot or mold. Achieving Passive House levels of airtightness requires precise design in the studio and discipline on the job site to ensure the air sealing is done correctly. What the discipline produces goes beyond a number on a calibrated fan. It results in a building that holds 70°F when the power's out for three days in February; an apartment where outdoor smoke and pollution stay outside because every cubic foot of fresh air comes through a filter, not a wall crack; a retrofit where the masonry behind sheathing finally stops icing up because warm humid interior air no longer leaks into a cavity that sits at 20°F.

While exceptional airtightness is universal across all Passive House projects, not all Passive House projects measure airtightness the same way. PHI requires ≤0.6 ACH50 (volume-based); Phius CORE requires ≤0.060 CFM50/sf (envelope-area-based), tightened to ≤0.040 CFM50/sf for their prescriptive path. Phius's metric scales consistently regardless of building geometry, a useful property when the same standard has to govern a single-family home and a high-rise. Retrofits get slightly more leeway. EnerPHit, PHI's retrofit standard, relaxes the threshold to 1.0 ACH50, while the retrofit standard for Phius (REVIVE) has its own retrofit-specific targets.

The metrics differ; the discipline doesn't, and air sealing specialists from across the world stress the importance of testing the air barrier as you build. Their reasoning is simple: every leak found at rough-in is one that doesn't have to be chased after the wall is closed.

People assume Passive House airtightness is some huge feat. Really, it's about the right materials and attention to detail. Want proof? A 264,000-square-foot high school in Bellingham, Washington built to standard energy code (not Passive House) tested at 0.39 ACH50 (0.095 CFM per square foot of envelope at 75 Pa). That's well below PHI's airtightness threshold of 0.6 ACH50. The team was just trying to meet code by applying a fluid-applied air barrier system to a conventional building. With the right materials and diligence, they cleared the Passive House airtightness bar without aiming for it.

The concepts in this hub trace what steps teams need to take to make an airtight building from both the design side and the construction side.

  • Deciding on the right building material given specific conditions is crucial, and different kinds of barriers—peel-and-stick, mechanically fastened, fluid-applied, sheet goods—are suited to specific construction contexts.

  • Continuity at junctions is where most buildings fail, so certain areas need special attention, including slab-to-wall, wall-to-roof, floor-plate-through-masonry, and the trade boundaries where one scope's tape has to find the next scope's membrane.

  • Penetration sealing without sloppy spray foam, with service cavities that move wires and pipes inboard of the air barrier.

  • Blower door testing is the construction-management spine—a four-stage protocol that gates each phase from air-barrier commissioning through final compliance, with smoke pencils, fog machines, and infrared cameras finding what the fan only counts.

  • Multifamily compartmentalization isolates each unit on its own pressure plane.

  • Retrofit airtightness where the existing building has its own opinion about where the air is.

  • Prefab and factory air-sealing where panels arrive pre-tested and assembly is the variable.

  • Workforce training programs build the hands-on competence required to seal at scale.

  • And vapor control—because the membrane that handles air also has to handle moisture.

Get this layer right and everything above it works. Get it wrong and the rest of the building can't compensate.


Frequently Asked Questions

PHI certification requires ≤0.6 air changes per hour at 50 pascals of pressure (0.6 ACH50). Phius CORE requires ≤0.060 CFM50 per square foot of gross envelope area, tightened to ≤0.040 for the prescriptive path. Both are dramatically tighter than code minimums—roughly five times tighter than the 2021 International Residential Code in U.S. climate zones 3-8. The thresholds differ because PHI and Phius use different metrics and certification pathways, not because they disagree on the physics.

A blower door test pressurizes or depressurizes a building to 50 pascals using a calibrated fan mounted in an exterior door, then measures the airflow required to maintain that pressure differential. The result expresses the building's air leakage rate. Tests should run during construction—pre-drywall at minimum—not just at final certification, because leakage paths identified during construction can be repaired while they're still accessible.

There are two answers, depending on whether you mean design or construction. Ed May of bldgtyp puts the planning failure first: not knowing which layer is the air barrier, and not having detailed how it transitions between assemblies. On site, the recurring physical failures are door and window seals, electrical and plumbing penetrations, and the assembly-to-assembly transitions where membrane laps and tape adhesion are easy to get wrong.

Airtightness is fundamentally a moisture and indoor air quality strategy, not only an energy strategy. Even in mild climates, uncontrolled airflow carries indoor humidity into wall cavities where it can condense, and carries outdoor pollutants into living spaces. In climates like Ireland's Atlantic coast, wind-driven rain at persistent pressure overwhelms gravity drainage—airtightness becomes a durability requirement. In dry climates like Adelaide, internally generated humidity from cooking, washing, and breathing accumulates without ventilation control. The energy savings are real but not the whole case.

Key Claims

Jens Lüder Herms
Pro Clima

A single 1 mm gap in an airtightness layer allows 1,600 times more moisture into a wall assembly than diffusion through an intact barrier—from a controlled experiment at Germany's Fraunhofer Institute that fundamentally reshaped how the field treats air control and vapor control as a single design problem.

From: Bonus Episode: Jens Lüder Hermes, pro clima (IPHC 2023)

Ed May
bldgtyp

The number one way to ruin a blower door score is a planning failure: not knowing which layer is the air barrier, how it transitions between assemblies, or whether the specified products actually adhere to one another.

From: 10 Ways to Ruin Your Blower Door Score (and Remedies)

Jessica Allen
Climasure

Australia's National Construction Code now requires a Class 4 vapor-permeable membrane in climate zones four through eight, with WUFI hygrothermal modeling demonstrating a mold-growth risk score of three or below on a one-to-six scale as the performance pathway.

From: Passive House Podcast Ep. 126 with Jessica Allen of Climasure